Support – Tech Note 49

       

EnGenius ENS202EXT Access Point

EnGenius ENS202EXT Access Point for Oilfield Service

Equipment needed:

  • EnGenius ENS202EXT
  • 2 Ethernet cords

Connecting the AP (Access Point)

  1. Remove the rear bottom panel
  2. Connect one end of the Ethernet cable into LAN(PoE) port of the AP and the other end to the PoE Ethernet port on the PoE injector (For a visual of steps 2-4, refer to Figure 1)
  1. Connect the power adapter to the DC-IN port of the AP and plug the other end into an electrical outlet.
  2. Connect the second Ethernet cable into the LAN port of the PoE injector and the other end to the Ethernet port on the computer
  3. Place the panel removed from step 1 back into the device.
  4. Screw on the provided antenna/s to the top of device

EnGenius ENS202EXT Access Point Oilfield Network Hardware

Figure 1

IP Address Configuration

  1. Once your computer is on, ensure that your TCP/IP is set to ON or enabled. Open Network Connections and then click local area connection. Under properties select Internet Protocol Version 4 (TCP/IPv4)
  2. If your computer is already on a network, ensure that you have set it to a Static IP Address on the interface as seen in Figure 3

EnGenius ENS202EXT Access Point IP Address Configuration

Figure 3

AP Bridge Setup

  1. Click on the internet symbol located at the bottom right hand corner of your screen. Switch your network to EnGenius  shown in Figure 4

EnGenius ENS202EXT Access Point AP Bridge for Oilfield Applications

Figure 4

  1. To configure the AP, open a web browser. In the address bar of the web browser, enter 192.168.1.1 and hit enter

EnGenius ENS202EXT Access Point Configuration

Figure 5

  1. A login screen will appear. By default, the username of the AP is admin and the password is admin. Enter the current username and password of the AP and then click Login
  2. This device will need to be set to mode Access Point. Click on the Operation Mode link under the System Properties. Save and apply

EnGenius ENS202EXT Access Point / Client Bridge for Remote Well Access

Figure 6

IP Settings

In order to connect with the Rapidlogger. We will have to change the IP settings from the default one.

  1. As figure 6 shows we will be changing the following:
  IP Address: 192.168.0.2
IP Subnet Mask: 255.255.255.0
Default Gateway: 192.168.0.1

EnGenius ENS202EXT Access Point for Rapidlogger

Figure 7

  1. Once this is complete click Save/Reload: under Status located in the yellow (far left)
  2. Click Save & Apply and exit this browser
  3. Disconnect the Ethernet from your computer and plug into Rapidlogger. Turn on the Rapidlogger.

EnGenius ENS202EXT Access Point Ethenet for Remote Areas

Figure 8

  1. Click on the internet symbol located at the bottom right hand corner of your screen. Switch your network to EnGenius
  2. Click the internet symbol again and click Open Network and Sharing Center
  3. Select on the left, Change adapter settings
  4. Follow step 7
  5. Switch the setting to obtain an IP address automatically
  6. Click okay
  7. Click okay
  8. Double click on the Wireless Network Connection
  9. Under properties change its IPv4 to Use the following IP address and input:
  IP address: 192.168.0.88 (last number can be whatever you would like except 5. This is the Rapidlogger’s IP address)
Subnet mask: 255.255.255.0
Default gateway: 192.168.0.1


EnGenius ENS202EXT Access Point Wireless Oilwell Access

Figure 9

  1. Open command prompt and type in: ipconfig. You should see under Wireless LAN adapter your IPv4 address you just setup here as in figure 10

Wireless Oilwell Monitoring Software

Figure 10

  1. Next type: ping 192.168.0.88 and hit enter. You should see 4 sent and 4 received. This means you are connected/communicating well between your computer to the Engenius.
  2. Now let’s check from computer to Rapidlogger. Type: ping 192.168.0.5 and hit enter. We should see the same, 4 sent and 4 received.
  3. Last go into the RapidVU software and try to run. If Rapidlogger word and circle light up green, then you are connected.
  4. You are now able to communicate to the Rapidlogger system from your computer.

Mounting the WiFi Engenius

  1. 31. Mount your Engenius somewhere close by your Rapidlogger system. This is usually done with tie wraps to a pole as seen in figure 11

Mount your Engenius somewhere close by your Rapidlogger system.

Figure 11

 